               Chapter 32
               Response Surface Methodology
               We describe regression analyses in this chapter that can deal with quadratic (but
               not higher, typically) terms or, equivalently, curvature in the response surface. Two
               types of response surface regressions are discussed: central composite response surface
               designs and optimal response surface designs.
               32.1      Response Surface Experiments
               Welook at the following coding scheme in this section,
                                          actual level − high level+low level
                                    X =                            2
                                      j           high level−low level
                                                            2
               Coding schemes are used in the response surface regression analyses, described in
               later sections.
               Exercise 32.1 (Response Surface Experiments)
               Consider the effect of air temperature and noise on the rate of oxygen consumption
               of mice. Two factors are studied, with the following low and high levels.
                                       factor        low level, −1  high level, 1
                                  temperature, X         0o F           30o F
                                                  1
                                      noise, X2         10 dB          100 dB
               and where the regression equation is
                         Y =β X +β X +β X +β X X +β X2 +β X2 +ε
                          i    0  0    1  i1    2 i2    12  i1 i2    11 i1    22  i2   ijk
                                                       297
             298              Chapter 32. Response Surface Methodology (ATTENDANCE 14)
                1. Using the coding scheme for X1
                   The coded version of X1 = 0 is
                                          actual level − high level+low level
                                  X =                             2
                                    j            high level−low level
                                                          2
                                          0−30+0
                                      =        2   =
                                            30−0
                                              2
                   (choose one) −1 / 0 / 1
                   and the coded version of X1 = 30 is
                                                     30−30+0
                                             X =           2   =
                                               j        30−0
                                                         2
                   (choose one) −1 / 0 / 1
                   and the coded version of X1 = 20 is
                                                     20−30+0
                                             X =           2   =
                                               j        30−0
                                                         2
                   (choose one) −1 / 1 / 1
                                     3
                   and the coded version of X1 = 40 (larger than the high value) is
                                                     40−30+0
                                             X =           2   =
                                               j        30−0
                                                         2
                   (choose one) −1 / 1 / 25
                                     3  15
                   and so, in summary,
                                         temperature, X1  coded value
                                                0             −1
                                               30              1
                                               20          1 = 0.333
                                                           3
                                               40          25 = 1.667
                                                           15
               Section 1. Response Surface Experiments (ATTENDANCE 14)                         299
                 2. Using the coding scheme for X2
                    The coded version of X2 = 10 is
                                              actual level − high level+low level
                                     X =                               2
                                       j              high level−low level
                                                               2
                                              10−100+10
                                          =          2    =
                                                100−10
                                                   2
                    (choose one) −1 / 0 / 1
                    and the coded version of X2 = 100 is
                                                        100− 100+10
                                               X =               2    =
                                                 j         100−10
                                                              2
                    (choose one) −1 / 0 / 1
                    and the coded version of X2 = 200 is
                                                        200− 100+10
                                               X =               2    =
                                                 j         100−10
                                                              2
                    (choose one) −1 / 1 / 145
                                        3   45
                    and so, in summary,
                                                noise, X2  coded value
                                                   10           −1
                                                   100           1
                                                   200      145 = 3.22
                                                             45
                 3. Coding scheme property
                    True / False The coding scheme,
                                            actual level − high level+low level
                                      X =                             2
                                        j           high level−low level
                                                              2
                    gives values inside the interval (1,−1) for levels between the high and low values,
                    and values outside (−1,1) for levels either below the low value or above the high
                    value.
             300              Chapter 32. Response Surface Methodology (ATTENDANCE 14)
                4. Review: coding scheme for 22 factorial design
                   True / False The coding scheme for a 22 factorial design is,
                                         temperature, X1  coded value
                                                0             −1
                                               30              1
                                            noise, X2     coded value
                                               10             −1
                                               100             1
                5. Coding scheme for 32 factorial design
                   True / False The coding scheme for a 32 factorial design is,
                                         temperature, X1  coded value
                                                0             −1
                                               15              0
                                               30              1
                                            noise, X2     coded value
                                               10             −1
                                               55              0
                                               100             1
                   where, notice, both factors have three levels each.
                6. Coding scheme for 52 factorial design
                   True / False The coding scheme for a 52 factorial design is,
                                       temperature, X1    coded value
                                                          √
                                             -6.21       − 2=−1.414
                                              0               −1
                                              15               0
                                              30          √ 1
                                             36.21          2 = 1.414
                                           noise, X2      coded value
                                                          √
                                             -8.64       − 2=−1.414
                                              10              −1
                                              55               0
                                             100          √ 1
                                            118.64          2 = 1.414
The words contained in this file might help you see if this file matches what you are looking for:

...Chapter response surface methodology we describe regression analyses in this that can deal with quadratic but not higher typically terms or equivalently curvature the two types of regressions are discussed central composite designs and optimal experiments welook at following coding scheme section actual level high low x j schemes used described later sections exercise consider eect air temperature noise on rate oxygen consumption mice factors studied levels factor o f db where equation is y i ijk attendance using for coded version choose one larger than value so summary property true false gives values inside interval between outside either below above review factorial design a notice both have three each...