jagomart
digital resources
picture1_Hrms Sample Submission Guidelines | Sample Submission


 206x       Filetype DOCX       File size 0.03 MB       Source: www.utoledo.edu


File: Hrms Sample Submission Guidelines | Sample Submission
hrms sample submission guidelines the following guidelines describe sample submission for accurate mass measurement of organic and inorganic molecules samples will be analyzed using an electrospray ionization esi quadrupole time ...

icon picture DOCX Filetype Word DOCX | Posted on 07 Jul 2022 | 3 years ago
Partial capture of text on file.
                                         HRMS sample submission guidelines
               The following guidelines describe sample submission for accurate mass measurement of organic
               and inorganic molecules. Samples will be analyzed using an electrospray ionization (ESI)-
               quadrupole time-of-flight (Q-TOF) mass spectrometer. Using this instrument, mass 
               measurements with mass accuracy of ~5 ppm can be achieved.   
                      Samples should be pure. Purity should be checked using low-resolution MS, NMR, or 
                       elemental analysis. It is recommended that you analyze the samples using NMR and the 
                       ion trap MS instrument supervised by Dr. Kim (or another mass spectrometer), and 
                       provide low-res MS data with the sample.
                      If preliminary MS data are available, your pure samples that are dissolved in HPLC grade 
                       solvents may be suitable for analysis. 
                      Solid samples should be submitted in a labeled glass vial. Mass submitted and storage 
                       conditions should be specified. Commonly, up to 1 mg of sample is sufficient to dilute 
                       the samples and perform the measurements.
                      Contaminants that may interfere with analyte ionization and instrument contamination, 
                       such as detergents, polymers, buffers and salts, should not be present in the samples. 
                      Before ESI-MS analysis, samples are commonly dissolved in HPLC-grade acetonitrile, 
                       water, or methanol. Aromatic solvents, as well as DMSO and DMF, are not suitable for 
                       ESI-MS analyses.   
                      For samples analyzed in positive ion mode, a small amount (0.1%) of formic acid is 
                       commonly added to obtain protonated ions. If your sample is acid sensitive, please 
                       specify in advance. 
                      If there is any safety concern regarding your sample, it must be addressed before the 
                       analysis.
                      You are welcome to discuss your sample preparation requirements with Ms. Sandhya 
                       Adhikari (Dr. Kirchhoff’s group) Samples should be submitted to her.
                                                                             HRMS Sample submission Form
                              Date: 
                              Research Group:
                              Student Name:
                                Sample Name                   Molecular               Molecular                 Exact              Amount                 Compatible
                                                                Formula                 Weight                  Mass             submitted                  Solvents 
                              Please provide any available information regarding previous sample analysis, sample purity, 
                              storage conditions, solubility, and sensitivity to low amounts of formic acid below. Circle all 
                              that apply.
                              NMR                                                 Available        Spectrum Attached                        Not Available 
                              Low-Res MS                                           Available        Spectrum Attached                       Not Available
                                                                                                                     o                               o
                              Sample Storage conditions              Room T                       4  C                                           -20  C
                              Contaminants present                           Yes                          No
                              Additional Comments: 
The words contained in this file might help you see if this file matches what you are looking for:

...Hrms sample submission guidelines the following describe for accurate mass measurement of organic and inorganic molecules samples will be analyzed using an electrospray ionization esi quadrupole time flight q tof spectrometer this instrument measurements with accuracy ppm can achieved should pure purity checked low resolution ms nmr or elemental analysis it is recommended that you analyze ion trap supervised by dr kim another provide res data if preliminary are available your dissolved in hplc grade solvents may suitable solid submitted a labeled glass vial storage conditions specified commonly up to mg sufficient dilute perform contaminants interfere analyte contamination such as detergents polymers buffers salts not present before acetonitrile water methanol aromatic well dmso dmf analyses positive mode small amount formic acid added obtain protonated ions sensitive please specify advance there any safety concern regarding must addressed welcome discuss preparation requirements sandh...