jagomart
digital resources
picture1_Family Therapy Pdf 89831 | Ta2 1 Crta


 259x       Filetype PDF       File size 0.23 MB       Source: www.hitachi-hightech.com


File: Family Therapy Pdf 89831 | Ta2 1 Crta
new thermal analysis techniques tma ss acta stress strain control ac control ta tma ta dma crta conventional ta ta x controlled rate ta hybrid ta highway ta tg ir ...

icon picture PDF Filetype PDF | Posted on 15 Sep 2022 | 3 years ago
Partial capture of text on file.
                  
                        New Thermal Analysis Techniques 
                                     TMA/SS                                ACTA 
                                Stress Strain Control                  AC Control TA 
                                        TMA                  TA             DMA,
                               CRTA                   Conventional TA                TA-X 
                         Controlled Rate TA                                        Hybrid TA 
                                                    Highway TA                TG-IR, MS, GC/MS
                                                     TG/DTA, DSC 
                  
                  
                 In addition to the conventionally used thermal analysis techniques, new thermal 
                 analysis techniques have attracted attention in recent years. The below 
                 techniques that have especially attracted attention are explained in the following 
                 chapters. 
                  
                 1. Controlled Rate Thermal Analysis 
                 2. Highway TA 
                 3. Hybrid Thermal Analysis 
                 2. New Techniques of Thermal Analysis 
              
                                              
               1. Controlled Rate Thermal Analysis 
                                        (CRTA) 
                                               
                                               
                ・A family of techniques which monitors the 
                  temperature-versus-time profile needed to 
                  maintain a chosen, fixed rate of change of a 
                  property of the sample in a specified atmosphere. 
                - For example, in controlled-rate experiments, power 
                  to the furnace is controlled to ensure a fixed rate 
                  of mass loss (or gain). 
              
              
             Controlled Rate Thermal Analysis is abbreviated as CRTA. 
             The above is the definition for CRTA from “For Better Thermal Analysis and 
                         rd
             Calorimetry” 3  Ed. (1991) published by ICTAC. 
             Although CRTA deviates from the original definition of thermal analysis, it is 
             specially defined as thermal analysis as it is often conducted using thermal 
             analysis devices. 
             While temperature is programmed and mass is measured in thermal analysis, 
             mass is programmed and temperature is calculated in CRTA. 
             This relationship is shown in the next page. 
             2. New Techniques of Thermal Analysis 
                 
                                                         
                                                         
                            TA and CRTA Comparison 
                       Control Subject Operation  Measurement 
                                                       Object                Object 
                     TA          Δ(Tp, Tr)        Heater Control        P (physical qty) 
                   CRTA         Δ(Pp, Pr)         Heater Control        T (temperature) 
                 
                          Tp: program temperature        Tr: control object temperature 
                        Pp: program physical quantity      Pr: control object quantity 
                The above shows comparisons of control subject, operation quantity and 
                measurement quantity between CRTA (Controlled Rate Thermal Analysis) and 
                TA (Thermal Analysis). 
                In TA, electricity to the heater is controlled against the difference between the 
                program temperature and the control subject temperature, and the resulting 
                physical quantity of the sample is measured. 
                In CRTA on the other hand, electricity to the heater is controlled against the 
                difference between the programmed physical quantity and the control subject 
                physical quantity, and the resulting sample temperature is measured. 
                In essence, TA and CRTA are two measurement techniques whose control 
                subject and the measurement object are reversed. 
                2. New Techniques of Thermal Analysis 
            
                       Actual CRTA Control 
                    Program            
                physical quantity                TA Control Loop
                             .  .      
                             T=f(P)
            
            
                                      Program 
                                      temperature (Tp) 
            
                           Control object           ∆T
                           temperature (Tr)
            
                            Heater            PID
                            Power 
                            Physical 
                            quality (p)
            
            
           The above diagram shows an actually used CRTA control loop. 
           In reality, it is difficult to directly control the heater without using the measured 
           temperature from the physical quantity feedback, so a two-fold control loop is 
           used as shown above. 
           2. New Techniques of Thermal Analysis 
The words contained in this file might help you see if this file matches what you are looking for:

...New thermal analysis techniques tma ss acta stress strain control ac ta dma crta conventional x controlled rate hybrid highway tg ir ms gc dta dsc in addition to the conventionally used have attracted attention recent years below that especially are explained following chapters of a family which monitors temperature versus time profile needed maintain chosen fixed change property sample specified atmosphere for example experiments power furnace is ensure mass loss or gain abbreviated as above definition from better and rd calorimetry ed published by ictac although deviates original it specially defined often conducted using devices while programmed measured calculated this relationship shown next page comparison subject operation measurement object tp tr heater p physical qty pp pr t program quantity shows comparisons between electricity against difference resulting on other hand essence two whose reversed actual loop f pid quality diagram an actually reality difficult directly without...

no reviews yet