jagomart
digital resources
picture1_Society Pdf 87515 | Application Note A Comparison Of Yeast Cell Counting Methods Luna Ii Yf Automated Yeast Cell Counter Vs Flow Cytometry V Hemocytometer


 168x       Filetype PDF       File size 0.35 MB       Source: directus.biocat.com


File: Society Pdf 87515 | Application Note A Comparison Of Yeast Cell Counting Methods Luna Ii Yf Automated Yeast Cell Counter Vs Flow Cytometry V Hemocytometer
applicationnote a comparison of yeast cell countingmethods luna iiyf automatedyeastcellcountervs flowcytometryvs he mocytometer introduction yeast is essential to the beer and wine industries as it con verts carbohydrates into co ...

icon picture PDF Filetype PDF | Posted on 14 Sep 2022 | 3 years ago
Partial capture of text on file.
            applicationnote
            A comparison of yeast cell countingmethods:
            LUNA-IIYF™AutomatedYeastCellCountervs.flowcytometryvs.  he
            mocytometer
                                                              Introduction
                                                              Yeast is essential to the beer and wine industries as it con
                                                              verts carbohydrates into CO and alcohol in a process kno
                                                                                        2
                                                              wnas fermentation. Accurate yeast cell counts are crucial
                                                              for initiating and monitoring the fermentation process. Th
                                                              e standard yeast counting method recommended by the
                                                              American Society of Brewing Chemists (ASBC) involves a h
                                                              emocytometer and a microscope. Although it is a simple
                                                              procedure, it is labor-intensive and prone to user-to-user
                                                              variability. Flow cytometry is another option but requires e
                                                              xpensive equipment, more reagents, and extensive trainin
                                                              g. The LUNA-II YF™Automated Yeast Cell Counter from Logo
                                                              s Biosystems was developed to be a simple and reproduci
                                                              ble solution for yeast cell counting. This application note c
                                                              ompares thethreemethodshere.
                                                              LUNA-IIYF™AutomatedYeastCellCounter
                                                              The LUNA-IIYF™Automated Yeast CellCounter is a fully auto
                                                              mated solution for yeast cell counting and viability analysis
                                                              that fits on any benchtop. Dual fluorescence optics, an aut
                                                              ofocusing liquid lens, and a proven counting algorithm pro
                                                              duce cell count and viability data in just 15 seconds, doing
                                                              away with the subjectivity and time of manual cell countin
                                                              g. The LUNA-II YF™eliminates the subjectivity of operator ju
                                                              dgment and guarantees that cells are counted with the sa
                                                              me criteria between counts and users. Data may be trans
                                                              ferred to a USB drive or printed on an external printer for e
                                                              ffortless recordkeeping. The LUNA-II YF™also generates co
                                                              mprehensive PDFreports with count data, protocols, corre
                                                              spondingcellimages,andrelevanthistograms.
              Accuracy compared to aflow cytometer
              To evaluate the accuracy of the LUNA-II YF™, cell counts                3.50E+06
              were compared to those obtained with the BD FACSC                                                       R² =0.9967
              alibur™ flow cytometer (BD Biosciences). Serial dilutions             L)
              of Sacchromycescerevisiaewere counted in triplicate. For the L        /m2.50E+06
              UNA-II YF™, yeast cells were labeled with Acridine Orang              (cells
              e/Propidium Iodide Stain, loaded into a disposable Phot               ™
                                                                                    F
                                                                                    Y
                                                                                     
                                                                                    I
              onSlide™, and counted with the default AO-PI protocol.                AI-1.50E+06
              For the flow cytometer, yeast cells were labeled with                 LUN
              a thiazole orange/propidium iodide stain and standar
              d beads were added to help determine cell concentra
                                                                                      5.00E+05
              tion. There was no significant difference between the                       5.00E+05       1.50E+06      2.50E+06      3.50E+06
              LUNA-II YF™ and the flow cytometer in determining cell                                    Flow cytometer(cells/mL)
              concentration (Fig 1) or cell viability (Fig 2), demonstrat        Figure 1. Comparison of the yeast cell concentration results from 
              ing the accuracyand reliability of the LUNA-II YF™.                              ™ 
                                                                                 the LUNA-II  YF and a flowcytometer.
              Variability compared to a  hemocytomete                            A                              B
              r and flowcytometer
                                                                                                                 100%
              Tocompare the variability of cell concentrations obtaine                                            90%
              d with the LUNA-II YF,flow cytometer, and hemocytomet                                               80%
              er, serial dilutions were prepared and counted in triplic                                           70%        Flowcytometer  
              ate. To test the hemocytometer (Marienfeld), cell samp                                             )60%        LUNA-Ⅱ-YF™
              les were mixed with an equal volume of 0.4% trypan bl                                              (%ity50%
                                                                                                                 labi
              ue stain. The cells were imaged with the iRiS™Digital Cel                   46%                    Vi40%
              l Imaging System and the cells within the four corner s                                             30%
              quares of the Neubauer counting grids were counted.                                                 20%
              There is no significant difference in the total concentra                                           10%
              tions between any of the methods (Fig 3). However, th                                                0%
              e hemocytometer showed a higher variability from cou
              nt to count whereas the LUNA-II YF™and the flow cytom              Figure 2. Comparison of the yeast viability results from the LUNA-
              eterweremoreconsistent.                                            II YF™ and  flow cytometer. (A) Viability results measured by the fl
                                                                                 ow cytometer. (B) There  was no significant difference in the viabil
                                                                                 ity results obtained with the two  instruments.
               Summary
                                                                                         5.00E+06
               The LUNA-II YF™Automated Yeast Cell Counter is a cost-                                                     Flow cytometer
               efficient and simple alternative to expensive flow cyto               L)  4.00E+06                         LUNA-Ⅱ-YF™
               meters as well as being faster and more accurate than                 ls/m                                 Hemocytometer
               manualcellcounting.                                                   (cle3.00E+06
                  • Simple –cell count and viability data in just 15  seco           ntio
                                                                                     antr2.00E+06
                    ndswithafewtapsonthetouchscreen                                  nce
                  • Reliable –no user-to-uservariability                             oC  1.00E+06
                  • Accurate –a tried, tested, and trusted cell counting  al             0.00E+00
                    gorithm                                                                          1        2       3        4        5
                                                                                                                    Dilution
                  • Convenient –automatically generated data reports  wi
                    thcellimages,histograms,protocols,anddata                    Figure 3. Comparison of the variability of results from a flow cytom
                                                                                 eter, the  LUNA-II YF™, and a hemocytometer. The variability of res
                                                                                 ults is greater for the  hemocytometer than for the other two instr
                                                                                 uments.
                OrderingInformation
                     LUNA-II YF™ Automated Yeast Cell Counter
                              Counter                       L50001          LUNA-II YF™ Automated Yeast CellCounter                                           1unit
                                                            L12005          PhotonSlide™, 50Slides                                                            1box
                                                            L12006          PhotonSlide™, 500Slides                                                         10boxes
                                Slides                      L12007          PhotonSlide™, 1000Slides                                                        20boxes
                                                            L12011          LUNA™ ReusableSlide                                                               1unit
                                                            L12012          LUNA™ ReusableSlides                                                             2 units
                                                            L12014          LUNA™ ReusableSlide Coverslips                                                  10 units
                                                            F23001          Acridine Orange/Propidium IodideStain                                          2 x 0.5mL
                                                            F23002          Acridine OrangeStain                                                           2 x 0.5mL
                                                            F23003          Propidium Iodide Stain                                                         2 x 0.5mL
                                                            F23004          Propidium Iodide Stain for Yeast                                               2 x 0.5mL
                              Reagents                      F23211          Fluorescein DiacetateStain                                                     2 x 0.5mL
                                                            F23213          Fluorescence Signal Enhancer1                                                  2 x 0.5mL
                                                            F23212          Cell Dilution Buffer                                                            5 x 20mL
                                                            F53002          Cell Dilution Buffer II                                                         5 x 20mL
                                                            F23202          Yeast Viability Kit 1                                                              1kit
                               Beads                        F23102          LUNA™ Fluorescence CalibrationBeads                                             2 x 1mL
                               Printer                      P10001          LUNA™Printer                                                                      1unit
                  Find out more at  www.logosbio.com
                                                                                             HEADQUARTERS          E-mail : info@logosbio.com              Tel : +82 31 478 4185
                                                                                             USA                   E-mail : info@logosbio.com              Tel : +1 703 622 4660
                                        www.logosbio.com                                     FRANCE                E-mail : info-france@logosbio.com       Tel : +33 (0)3 74 09 44 35
The words contained in this file might help you see if this file matches what you are looking for:

...Applicationnote a comparison of yeast cell countingmethods luna iiyf automatedyeastcellcountervs flowcytometryvs he mocytometer introduction is essential to the beer and wine industries as it con verts carbohydrates into co alcohol in process kno wnas fermentation accurate counts are crucial for initiating monitoring th e standard counting method recommended by american society brewing chemists asbc involves h emocytometer microscope although simple procedure labor intensive prone user variability flow cytometry another option but requires xpensive equipment more reagents extensive trainin g ii yf automated counter from logo s biosystems was developed be reproduci ble solution this application note c ompares thethreemethodshere automatedyeastcellcounter cellcounter fully auto mated viability analysis that fits on any benchtop dual fluorescence optics an aut ofocusing liquid lens proven algorithm pro duce count data just seconds doing away with subjectivity time manual countin eliminate...

no reviews yet
Please Login to review.