245x Filetype PDF File size 2.23 MB Source: www.unitedutilities.com
Developer Services Construction Details Approved details • Developer Services Detail 1 – Manhole Type 1 • Developer Services Detail 2 – Manhole Type 2 • Developer Services Detail 3 – Manhole Type 4 • Developer Services Detail 4 – SW Shallow Manhole • Developer Services Detail 5 – Flow Control Manhole • Developer Services Detail 7 – External Backdrop Detail • Developer Services Detail 8 – Pipe Bedding Detail • Developer Services Detail 10 – Variable Manhole Features • Developer Services Detail 11 – Headwall Type 1 De tail • Developer Services Detail 12 - Headwall Type 2 and 3 Details Copyright © United Utilities Water Limited 2016 2 MANHOLE ACCESS. SEE NOTE 8 GROUND LEVEL WHERE COVER IS 350-600LOCATED IN FIELD LADDER OR DOUBLE STEPS AT 250/300 CENTRES NOTES VERTICALLY (v.f."A") 1. ALL DIMENSIONS ARE IN MILLIMETRES 2. CONCRETE BENCHING AND PIPE SURROUND PRECAST CONCRETE REDUCER SHALL BE PLACED IN SINGLE CONTINUOUS SLAB (v.f."B") OPERATION FROM TOP OF BASE SLAB TO TOP OF BENCHING AND PIPE SURROUND 3. CONNECTION INTO MANHOLES PRECAST CONCRETE CHAMBER 6000 MAX SHALL BE CONSTRUCTED WITH THE SOFFITS RING. LEVEL UNLESS DETAILED DIFFERENTLY ON CONTRACT DRAWINGS 4. METALWORK INCOMING INCOMING 100 MIN/200 MAX LADDERS, HANDRAILING AND SAFETY CHAIN CONNECTION CONNECTION THICKNESS OF SHALL BE AS SHOWN ON DEVELOPER SERVICES 2000 MIN BENCHING CONCRETE DETAIL 9 (STND/19/009) 150 MINIMUM CONCRETE BETWEEN OUTSIDE 5. CONCRETE SURROUND TO MANHOLES SURROUND TO BARREL & SOCKET TOP SURFACE OF PIPE SAFETY CHAIN (v.f."F") X MIN OF CUT PIPE (NOTES 2 & 10) 300 MAX1 IN 30 AND CHAMBER RING. A CONCRETE SURROUND IS NOT NORMALLY REQUIRED TO MANHOLES UNLESS INSTALLED IN A A MINIMUM RADIUS OF AREAS OF UNSTABLE GROUND, UNDER EXPOSED ARRISES TO CONDITIONS OF FLOTATION OR WHERE DOUBLE STEPS BE 40. BENCHING SUBJECTED TO EXCEPTIONAL OR ECCENTRIC AT 300 CENTRES 300 SURFACE WITH STEEL LOADS. IN WHICH CASES A 150 SURROUND OF AT VERTICALLY TROWEL FINISH. LEAST 20 N/mm CONCRETE SHALL BE CHANNEL SURFACES PROVIDED. ANY JOINTS SHOULD BE STAGGERED 225 THK CONCRETE FAIR WORKED. WITH PRECAST CONCRETE JOINTS BASE ( SEE NOTE 10) 6. MINIMUM LENGTH OF CHANNEL (X Min) COMPRESSIBLE FILLER 500 x 150 INVERT ACCESS STEP (v.f."G") 75 CONCRETE BLINDING HALF ROUND P.C.C. OR V.C. CHAMBER DIA ''X'' MIN INVERT TO FORM CHANNEL 1050 800 WHERE APPROPRIATE. SECTION B-B SECTION C-C 1200 950 1350 1000 1500 1050 1800 1150 2100 1300 2400 1450 2700 1550 3000 1700 CONCRETE BASE C 7. CUT ENDS OF REINFORCED CONCRETE PIPES INCOMING CONNECTION SHALL BE TREATED WITH EPOXY RESIN MINIMUM BENCHING PAINT/MORTAR A SC DH SD FOR INFORMATION 14.04.16 WIDTH (v.f."D") $1*/(12772(;&((' 8. MANHOLE ACCESSES FOR MANHOLE ACCESS OPTIONS AND DETAILS SEE DEVELOPER SERVICES DETAIL 10 (STND/19/010) B FLOW B DOUBLE STEPS SHALL BE PLASTIC ENCAPSULATED CARBON STEEL TO BS EN 1247-2. DOUBLE STEPS SHALL NOT BE USED WHERE COVER-TO-SOFFIT DIMENSION IS >3.0m ROCKER PIPE 325 MIN. MAX. LENGTH OF 9. COVER AND FRAME C ROCKER PIPE (v.f."C") 150 DEEP COVERS ARE TO BE USED IN CATEGORY 1, 2, 3 ROADS. 100 DEEP COVERS ARE CONCRETE BASE TO BE USED IN CATEGORY 4 ROADS. DOUBLE 750 MAX. DISTANCE OF FIRST PIPE TRIANGULAR COVERS ARE TO BE USED IN JOINT FROM CHAMBER SURROUND CARRIAGEWAY. ROAD CATEGORY TO BE SECTION A-A DESIGNATED BY THE HIGHWAY AUTHORITY. FRAME TO BE SET AS PER SPECIFICATION 10.CONCRETE MANHOLE TYPE 1 - PIPES NOT ALL IN-SITU CONCRETE TO BE DC - 3 OR FND3 EXCEEDING 525 DIAMETER 11.VARIABLE FEATURES (V.F.) (DEPTH TO BENCHING NOT EXCEEDING 6000) WHERE V.F. APPEARS IN ANNOTATION REFER TO VARIABLE FEATURES AS SHOWN ON DEVELOPER SERVICES DETAIL 10 (STND/19/010) c The copyright of this document, which contains information of a proprietary nature, is vested in United Utilities Water Limited. The content of this document may not be used for purposes other than that for which it has been supplied and may not be reproduced, either wholly or in part, in any way whatsoever. It may not be used by, or its contents divulged to any other person whatsoever without the prior written permission of United Utilities Water Limited. Copyright Acknowledgement: Use of Ordnance Survey map data sanctioned by the controller of H.M. Stationery Office. OS Licence Number 100019326. Crown copyright reserved. Unauthorised production infringes copyright MANHOLE ACCESS. SEE NOTE 8. GROUND LEVEL 350-600 WHEN COVER IS PRECAST CONCRETE COVER LOCATED IN FIELD SLAB (V.F.B) ACCESS LADDER PRECAST CONCRETE HANDRAILING WITH FLAT CHAMBER RING BASE FIXINGS AND ACCESS 150 MINIMUM THICKNESS CONCRETE 6000 MAX 600 OPENINGS (v.f."D"&"E") STEP IRON ABOVE SURROUND TO BARREL & SOCKET OF MIN SEE NOTE 4 PIPE AS HANDHOLD CUT PIPE (NOTES 2 & 10) 100 MIN/200 MAX THICKNESS OF 2000 MIN BENCHING CONCRETE BETWEEN OUTSIDE TOP NOTES INCOMING SURFACE OF PIPE AND CONNECTION 1 IN 30 CHAMBER RING 1. ALL DIMENSIONS ARE IN MILLIMETRES X MIN 2. CONCRETE BENCHING AND PIPE SURROUND SHALL BE PLACED IN SINGLE CONTINUOUS OPERATION MINIMUM RADIUS OF FROM TOP OF BASE SLAB TO TOP OF BENCHING AND 150 EXPOSED ARRISES TO PIPE SURROUND HALF ROUND PRECAST BE 40. BENCHING 3. CONNECTION INTO MANHOLES 225 CONCRETE INVERT TO FORM SURFACE WITH STEEL CHANNEL WHERE TROWEL FINISH. SHALL BE CONSTRUCTED WITH THE SOFFITS LEVEL COMPRESSIBLE SAFETY 500 x 150 RECESS+ APPROPRIATE. CHANNEL SURFACES UNLESS DETAILED DIFFERENTLY ON CONTRACT FILLER CHAIN ACCESS STEP FAIR WORKED DRAWINGS 225 THICK 75 CONCRETE 4. METALWORK CONCRETE BASE BLINDING CONCRETE BENCHING (NOTES 2 & 10) LADDERS, HANDRAILING AND SAFETY CHAIN SHALL BE SECTION B-B SECTION C-C AS SHOWN ON DEVELOPER SERVICES DETAIL 9 (STND/19/009) 5. CONCRETE SURROUND TO MANHOLES 700 A CONCRETE SURROUND IS NOT NORMALLY REQUIRED DROP BAR DETAIL TO MANHOLES UNLESS INSTALLED IN AREAS OF UNSTABLE GROUND, UNDER CONDITIONS OF FLOTATION OR WHERE SUBJECTED TO EXCEPTIONAL FIXED END DETAIL OR ECCENTRIC LOADS. IN WHICH CASES A 150 SURROUND OF AT LEAST 20 N/mm CONCRETE SHALL BE HOOK DETAIL PROVIDED. ANY JOINTS SHOULD BE STAGGERED WITH PRECAST CONCRETE JOINTS 1100 6. MINIMUM LENGTH OF CHANNEL (X Min) 100 100 SAFETY CHAIN IN 375 NORMAL POSITION CHAMBER DIA ''X'' MIN PREFERRED LADDER 500 1050 800 MINIMUM BENCHING AND ACCESS 1200 950 WIDTH 1100 POSITION 1350 1000 500 x 150 RECESS FLOW 1500 1050 C 1800 1150 DROP BAR DETAIL STAINLESS STEEL HANDRAILING DOUBLE STEPS AT 300 2100 1300 SAFETY CHAIN CTRS VERTICALLY 2400 1450 CONCRETE BASE SEE NOTE 11 2700 1550 STEP IRON ABOVE PIPE FRONT ELEVATION 3000 1700 OUTLET TO ALLOW SAFETY A SC DH SD FOR INFORMATION 14.04.16 CHAIN REMOVAL. TYPE 2 7. CUT ENDS OF REINFORCED CONCRETE PIPES MANHOLE ONLY FLOWB RING NUT FOR PARKING SHALL BE TREATED WITH EPOXY RESIN PAINT/MORTAR B CHAIN (NORMAL POSITION) 325MIN 8. MANHOLE ACCESSES FOR MANHOLE ACCESS COMPRESSIBLE FILLER STEP IRON FOR HOLDING OPTIONS AND DETAILS SEE DEVELOPER SERVICES THICKNESS "L" WHEN STOOD IN DETAIL 10 (STND/19/010). DOUBLE STEPS SHALL BE L 750 MAX. DISTANCE OF FIRST CHANNEL TYPE 2 ONLY PLASTIC ENCAPSULATED CARBON STEEL. DOUBLE REFER TO TABLE 3 C PIPE JOINT FROM CHAMBER 260 STEPS SHALL NOT BE USED WHERE COVER-TO-SOFFIT DWG NO. STND/19/008 SURROUND DIMENSION IS >3.0m 1 IN 30 1 IN 30 9. COVER AND FRAME DOUBLE STEPS AT 300 PIPE CONNECTION 125 MIN FROM TOP CTRS VERTICALLY 150 DEEP COVERS ARE TO BE USED IN CATEGORY 1, 2, 3 PLAN OF BENCHING ROADS. 100 DEEP COVERS ARE TO BE USED IN SAFETY CHAIN SHOWN IN CATEGORY 4 ROADS. DOUBLE TRIANGULAR COVERS 200 MAX100 MIN POSITION WHEN WORKING ARE TO BE USED IN CARRIAGEWAY. ROAD CATEGORY IN INVERT TO BE DESIGNATED BY THE HIGHWAY AUTHORITY. 1700 MAX FRAME TO BE SET AS PER SPECIFICATION MANHOLE TYPE 2 150 FOR TYPE 2 MANHOLES 10.CONCRETE PIPES 600 - 1500 DIAMETER 1 IN 30 300 FOR TYPE 1 MANHOLES ALL IN-SITU CONCRETE TO BE DC - 3 OR FND3 (DEPTH TO BENCHING NOT EXCEEDING 6000) 11.VARIABLE FEATURES (V.F.) WHERE V.F. APPEARS IN ANNOTATION REFER TO SIDE ELEVATION VARIABLE FEATURES AS SHOWN ON DEVELOPER (LOOKING DOWNSTREAM) SERVICES DETAIL 10 (STND/19/010) c The copyright of this document, which contains information of a proprietary nature, is vested in United Utilities Water Limited. The content of this document may not be used for purposes other than that for which it has been supplied and may not be reproduced, either wholly or in part, in any way whatsoever. It may not be used by, or its contents divulged to any other person whatsoever without the prior written permission of United Utilities Water Limited. Copyright Acknowledgement: Use of Ordnance Survey map data sanctioned by the controller of H.M. Stationery Office. OS Licence Number 100019326. Crown copyright reserved. Unauthorised production infringes copyright
no reviews yet
Please Login to review.