jagomart
digital resources
picture1_Analysis Ppt Repost 77690 | Forth Worth2004


 159x       Filetype PPT       File size 1.09 MB       Source: www.shsu.edu


File: Analysis Ppt Repost 77690 | Forth Worth2004
organo metalloid detection in headspace gases above bacteria methods of extraction manual gas syringe 1ml solid phase micro extraction spme instrumentation gas chromatography f induced 2 chemiluminescence detection gas chromatography ...

icon picture PPT Filetype Power Point PPT | Posted on 03 Sep 2022 | 3 years ago
Partial capture of text on file.
    Organo-metalloid detection in headspace gases 
    above bacteria
  Methods of Extraction
     Manual Gas Syringe (1mL)
     Solid Phase Micro Extraction (SPME)
  Instrumentation
     Gas Chromatography – F -induced 
                               2
       Chemiluminescence Detection
     Gas Chromatography – Mass 
       Spectrometry
                                           
     Geobacillus stearothermophilus V
      Resistant to TeO -2 and TeO -2
                            3            4
      Growth Conditions of this thermophile
         Temperature:  60º C
         Aerobic Environment
      Difficult to perform headspace analysis.
         Oxidation of organo-sulfides and tellurides.
         Volatiles are purged out of the headspace.
                                         
      Genetic Modification of E. Coli JM109 Cells
       Open Reading Frames (ORF)
          ORF 600 – UbiE methyltransferase
          ORF 780 – uroporphyrin-III C-methyltransferase (cobA)
          ORF 399 – BtuR protein
       pSP72 cloning vector
          Plasmid is coded for ampicillin resistance.
          DNA was inserted at the HindIII restriction site.
                                            
    GC- SCD  Chromatogram of E. Coli 1VH 
    Headspace
                               
    Methanetellurol
     Was the chromatographic peak dimethyl selenide or 
       methanetellurol?
     If so, that means the tellurium amendments were 
       contaminated with selenium.
     Boiling Point of CH SeCH  - 54º C
                         3      3
     Boiling Point of CH TeH – 57º C
                         3
                                  
The words contained in this file might help you see if this file matches what you are looking for:

...Organo metalloid detection in headspace gases above bacteria methods of extraction manual gas syringe ml solid phase micro spme instrumentation chromatography f induced chemiluminescence mass spectrometry geobacillus stearothermophilus v resistant to teo and growth conditions this thermophile temperature c aerobic environment difficult perform analysis oxidation sulfides tellurides volatiles are purged out the genetic modification e coli jm cells open reading frames orf ubie methyltransferase uroporphyrin iii coba btur protein psp cloning vector plasmid is coded for ampicillin resistance dna was inserted at hindiii restriction site gc scd chromatogram vh methanetellurol chromatographic peak dimethyl selenide or if so that means tellurium amendments were contaminated with selenium boiling point ch sech teh...

no reviews yet
Please Login to review.